4. SET CS Set the DMX channel patch for a CS-DMX control station.
PATCH Transfers the patch from CS-IPRO memory to control station memory.
The DMX channel patch data in the programmer memory is sent and saved into a
CS-DMX control station. The total transfer time to set the patch is approximately 110
milliseconds.
Point the CS-IPRO infrared LED window directly at the CS-DMX infrared LED
window, within 12" (30 cm).
SET CS Press EXECUTE to set the CS-DMX control station patch.
SENDING Displayed briey while data is being sent from the CS-IPRO.
OKAY Indicates data has been successfully transferred.
COMM ERR Indicates a communication error has been detected. Try again.
CRC ERR! Indicates a CRC data checking error has been detected. Try again.
KEY ERR! Indicates a security key error. Try again.
INVALID Indicates the security key data contains an invalid range. Try again.
5. GET CS Get the existing DMX channel patch from a CS-DMX control station.
PATCH Transfers the patch from control station memory to CS-IPRO memory.
The existing DMX channel patch is read from the CS-DMX control station and loads
the patch into the CS-IPRO transfer buffer. The data is checked and veried and
then loaded into the CS-IPRO memory. The patch can then be viewed in the CHECK
PATCH menu or modied in the EDIT PATCH menu.
Point the CS-IPRO infrared LED window directly at the CS-DMX infrared LED
window, within 12" (30 cm).
GET CS Press EXECUTE to get the CS-DMX control station patch.
CHECKING Displayed briey while data is being read and transferred.
OKAY Indicates data has been successfully transferred to the CS-IPRO.
COMM ERR Indicates a communication error has been detected. Try again.
DATA ERR Indicates a data error has been detected. Try again.
6. SAVE Save the DMX channel patch into the removable EEPROM Memory Module.
PATCH Saves the patch in the CS-IPRO memory only.
The DMX channel patch saved in the CS-IPRO memory is saved into the removable
EEPROM Memory Module. Note that previously saved DMX channel patch data in
the EEPROM Memory Module will be overwritten.
SAVE Press EXECUTE to enter the menu and save the DMX channel patch.
SURE ??? Press EXECUTE again to save the DMX channel patch. Are you sure?
DONE !!! Indicates the DMX channel patch has been successfully saved.
CRC ERR! Indicates a CRC data checking error has been detected. Try again.
TYPE ERR Indicates the wrong type of EEPROM memory module has been detected.
MEM ERR! Indicates a defective EEPROM memory module has been detected.
NO MEM ! Indicates an EEPROM memory module has not been detected (not installed).
Automatically exits the menu when the patch has been successfully saved.
7. LOAD Load the DMX channel patch from the removable EEPROM Memory Module.
PATCH Loads and saves the patch into the CS-IPRO memory.
The DMX channel patch saved in the EEPROM Memory Module is loaded and saved
into the CS-IPRO memory. Note the previous DMX channel patch data in the CS-
IPRO memory will be overwritten.
LOAD Press EXECUTE to enter the menu and load the DMX channel patch.
SURE !!! Press EXECUTE again to load the DMX channel patch. Are you sure?
DONE !!! Indicates the DMX channel patch has been successfully loaded.
CRC ERR! Indicates a CRC data checking error has been detected. Try again.
TYPE ERR Indicates the wrong type of EEPROM memory module has been detected.
MEM ERR! Indicates a defective EEPROM memory module has been detected.
NO MEM ! Indicates an EEPROM memory module has not been detected (not installed).